Combination IO Modules

2DI+2AI+2DO Industrial Remote IO Module (RS485,Ethernet)

Item No.: M100
Industrial Remote IO Module M100 is designed for IIOT applications and Industrial Automation, it compatible with SNMP, MQTT Protocol, Modbus RTU Protocol, Modbus TCP Protocol, equip with 2DI, 2DO, 2AI.
  • T Version: 1*RJ45+1RS485+2DI+2AI+2DO
  • E Version: 2*RJ45+1RS485+2DI+2AI+2DO
  • Introduction Features Specifications Download Applications
    Remote Input/Output Modules
    Remote Input/Output (I/O) Modules M100 is designed for IIOT applications and Industrial Automation, the remote I/O comes with 2 digital inputs, 2 digital outputs, 2 analog inputs, compatible with SNMP V1/V2, MQTT Protocol, Modbus RTU Protocol, Modbus TCP Protocol.
    Industrial Remote I/O Module M100 provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.
    The Input/Output module also has Ethernet port.
    2DI
    Wet/Dry Contact
    High speed pulse
    counting
    2DO
    SINK
    High speed pulse
    output
    2AI
    0-20mA/4-20mA
    0-5V
    0-10V
    Protocol
    SNMP V1/V2
    Modbus RTU/Modbus TCP
    MQTT

     
                                                    


    Item Parameter Description
    Power Input voltage
    1. Models without AO: 9~36VDC
    2. Models with AO: 24~36VDC
    Power consumption Typical standby power consumption: ≤ 2W
    Power Output
    1. 1 channel
    2. Output voltage: 936V DC
    3. Output current: 1500mA@12V(MAX)
    Protection Reverse wiring prevention;
    ESD Air: 15KV; Surge: 4KV
    Ethernet Specification 1 x RJ45, 10M/100Mbps
    Protection ESD contact: 8KV, Surge: 4KV(10/1000us)
    Protocol Modbus RTU, Modbus TCP, MQTT
    Serial port QTY 1 x RS485
    Baud Rate 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
    Data Bit 7, 8
    Parity Bit None, Even, Odd
    Stop Bit 0.5, 1, 1.5, 2
    Protocol Modbus RTU(slave), Modbus RTU(master)
    Protection ESD contact: 8KV  Surge: 4KV(8/20us)
    Digital input QTY 16 channel(Max)
    Type Support Wet contact(NPN, PNP) and Dry contact.
    Default: Wet contact
    Dry contact
    1. Close: Short circuit
    2. Open: Open circuits
    Wet contact
    1. Close: 10~30VDC
    2. Open: 0~3VDC
    Others Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz.
    Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz.
    Isolated protection 2KVrms
    Sampling Rate 100Hz
    Digital output QTY 16 channels(Max)
    Type SINK
    Capacity 500mA per contact
    Overvoltage protection 50VDC
    Pulse output The first DO supports pulse output, pulse output frequency: 10Hz~300KHz
    Analog input (12bit) QTY 8 channels(Max)
    Method Differential input
    Type 4-20mA, 0-20mA, 0-5V, 0-10V
    Resolution 12Bit
    Accuracy
    1. ±0.1% FSR @ 25°C
    2. ±0.3% FSR @ -10 and 60°C
    3. ±0.5% FSR @ -40 and 75°C
    Sampling Rate 20Hz
    Input Impedance
    1. Voltage type: >1M ohms
    2. Current type: 162 ohms
    Analog input (16bit) QTY
    1. 8 channels(Max)
    Method Differential input
    Type 4-20mA, 0-20mA, 0-5V, 0-10V
    Resolution
    1. 16Bit
    Accuracy
    1. ±0.5‰FSR @ 25°C
    Input Impedance
    1. Voltage type: >1M ohms
    2. Current type: 162 ohms
    Software Protocols IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT
    Protocol conversion Support Modbus TCP and RTU protocol conversion
    Support Modbus RTU to MQTT and Modbus TCP to MQTT
    Indicator light Power, Link, RS485_RXD, RS485_TXD, IO status
    User configuration PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10
    Map data bool: 300
    16bit: 300
    Login Package Support custom login package
    Heartbeat Package Support custom heartbeat package
    Environment Working -2070°C, 595%RH
    Storage -4085°C, 595%RH
    Others Case Metal
    Dimension 82mm×40mm×100mm
    Protection grade IP30
    Net Weight 450g
    Installation DIN rail mounted, Wall-mounted
    Description
    Remote Input/Output Modules
    Remote Input/Output (I/O) Modules M100 is designed for IIOT applications and Industrial Automation, the remote I/O comes with 2 digital inputs, 2 digital outputs, 2 analog inputs, compatible with SNMP V1/V2, MQTT Protocol, Modbus RTU Protocol, Modbus TCP Protocol.
    Industrial Remote I/O Module M100 provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.
    The Input/Output module also has Ethernet port.
    2DI
    Wet/Dry Contact
    High speed pulse
    counting
    2DO
    SINK
    High speed pulse
    output
    2AI
    0-20mA/4-20mA
    0-5V
    0-10V
    Protocol
    SNMP V1/V2
    Modbus RTU/Modbus TCP
    MQTT

     
                                                    


    introduction
    Features
    Specifications
    Item Parameter Description
    Power Input voltage
    1. Models without AO: 9~36VDC
    2. Models with AO: 24~36VDC
    Power consumption Typical standby power consumption: ≤ 2W
    Power Output
    1. 1 channel
    2. Output voltage: 936V DC
    3. Output current: 1500mA@12V(MAX)
    Protection Reverse wiring prevention;
    ESD Air: 15KV; Surge: 4KV
    Ethernet Specification 1 x RJ45, 10M/100Mbps
    Protection ESD contact: 8KV, Surge: 4KV(10/1000us)
    Protocol Modbus RTU, Modbus TCP, MQTT
    Serial port QTY 1 x RS485
    Baud Rate 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
    Data Bit 7, 8
    Parity Bit None, Even, Odd
    Stop Bit 0.5, 1, 1.5, 2
    Protocol Modbus RTU(slave), Modbus RTU(master)
    Protection ESD contact: 8KV  Surge: 4KV(8/20us)
    Digital input QTY 16 channel(Max)
    Type Support Wet contact(NPN, PNP) and Dry contact.
    Default: Wet contact
    Dry contact
    1. Close: Short circuit
    2. Open: Open circuits
    Wet contact
    1. Close: 10~30VDC
    2. Open: 0~3VDC
    Others Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz.
    Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz.
    Isolated protection 2KVrms
    Sampling Rate 100Hz
    Digital output QTY 16 channels(Max)
    Type SINK
    Capacity 500mA per contact
    Overvoltage protection 50VDC
    Pulse output The first DO supports pulse output, pulse output frequency: 10Hz~300KHz
    Analog input (12bit) QTY 8 channels(Max)
    Method Differential input
    Type 4-20mA, 0-20mA, 0-5V, 0-10V
    Resolution 12Bit
    Accuracy
    1. ±0.1% FSR @ 25°C
    2. ±0.3% FSR @ -10 and 60°C
    3. ±0.5% FSR @ -40 and 75°C
    Sampling Rate 20Hz
    Input Impedance
    1. Voltage type: >1M ohms
    2. Current type: 162 ohms
    Analog input (16bit) QTY
    1. 8 channels(Max)
    Method Differential input
    Type 4-20mA, 0-20mA, 0-5V, 0-10V
    Resolution
    1. 16Bit
    Accuracy
    1. ±0.5‰FSR @ 25°C
    Input Impedance
    1. Voltage type: >1M ohms
    2. Current type: 162 ohms
    Software Protocols IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT
    Protocol conversion Support Modbus TCP and RTU protocol conversion
    Support Modbus RTU to MQTT and Modbus TCP to MQTT
    Indicator light Power, Link, RS485_RXD, RS485_TXD, IO status
    User configuration PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10
    Map data bool: 300
    16bit: 300
    Login Package Support custom login package
    Heartbeat Package Support custom heartbeat package
    Environment Working -2070°C, 595%RH
    Storage -4085°C, 595%RH
    Others Case Metal
    Dimension 82mm×40mm×100mm
    Protection grade IP30
    Net Weight 450g
    Installation DIN rail mounted, Wall-mounted